Blomios b9fd2fb925 fix(terminals): stop PTY output duplication on re-attach
Each open/reattach spawned a pump thread feeding pty_bridge[session]. The
broadcast hub added a subscriber per attach without dropping the previous one,
and the stale pump thread kept delivering (its send_output still succeeded
against the new channel) — so every byte was delivered twice (more after
further re-attaches). Accumulated on each tab/layout/agent switch; window
resize made it glaring.

- Broadcast::subscribe() is now single-consumer: a new subscription supersedes
  the previous one, ending the old pump thread's stream.
- PtyBridge gains a per-session generation; register() returns it and
  unregister_if(session, gen) only removes when still current, so a dying
  superseded thread can't tear down the channel that replaced it.
- All three attach sites (open/reattach/agent launch) use unregister_if.

Tests: 6 added (generation guard + single-consumer broadcast). Workspace green.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>